Specifications PreciCura SR Road
|
PERFORMANCE
|
Metric
|
US
|
|
Stand off
|
200 mm
|
7.9"
|
|
Measurement range
|
200 mm
|
7.9"
|
|
Resolution (internal)
|
0.01 mm
|
0.001"
|
|
Resolution (at RS422 interface)
|
0.05 mm
|
0.002"
|
|
Sample speed
|
2 kHz
|
|
Detector type
|
CCD
|
|
Power supply
|
18-36 VDC
|
|
LASER
|
|
|
Wavelength
|
650-670 nm
|
|
Laser power
|
< 5mW
|
|
Laser class
|
3R
|
|
Enclosure
|
|
|
Dimension *
|
175x108x42 mm
|
6.89x4.25x1.65"
|
|
Weight
|
1.0 kg
|
2.2 lbs
|
|
Protections class
|
IP 65
|
|
Operating temperature
|
0 .. +40 °C
|
32 .. +104 °F
|
|
Storage temperature
|
-20 °C .. +70 °C
|
-4 °F .. +158 °F
|
|
Material
|
Laquered aluminium
|
|
Interfaces
|
|
|
Service interface
|
RS232
|
|
RS422 Clock/Data
|
Output rate 16 kHz (Compatible with Selcom)
|
|
Functions/Features
|
|
|
Measuring algorithm
|
Triangulation with modified "centre of gravity". Suppression of background light and second reflections.
|
*Incl. mounted angled M12 contact