LIMAB

PreciCura MR Road

Specifications PreciCura MR Road

PERFORMANCE

Metric

US

Stand off

300 mm (Customized)

11,8" (Customized)

Measurement range (MR)

1000 mm (Customized)

39,3" (Customized)

Resolution (at RS422 interface)

MR defined by range mask
4000

MR defined by range mask
4000

     

Sample speed

2 kHz

Detector type

CCD

Power supply

18-36 VDC

LASER

 

Wavelength

650-670 nm

Laser power

15 mW

Laser class

3B

Exposure time

3 – 500 µs

Enclosure

 

Dimension

331x148x56 mm

13.03x5.83x2.2"

Weight

3.0 kg

6.6 lbs

Protections class

IP 65

Operating temperature

0 .. +40 °C

32 .. +104 °F

Storage temperature

-20 °C .. +70 °C

-4 °F .. +158 °F

Material

Laquered aluminium

Interfaces

 

Service interface

RS232

RS422 Clock/Data

 Output rate 16 kHz (Compatible with Selcom)

Functions/Features

 

Measuring algorithm

Triangulation with modified "centre of gravity". Suppression of background light and second reflections.

* Incl. mounted angled M12 contact