LIMAB

PreciCura MR Standard

Specifications PreciCura MR Standard

PERFORMANCE

Metric

US

Stand off

100-2000 mm (Customized)

3.9"-78,7" (Customized)

Measurement range (MR)

200-600mm (Customized)

7.9"-23,6" (Customized)

Resolution (MR<320 mm)

0.01 mm

0.001"

Resolution (MR>320 mm)

0,1 mm

0.01"

Repeatability close end*

0.07 mm

0.0028"

Repeatability far end*

1.18 mm

0.046"

Sample speed

2 kHz

Detector type

CCD

Power supply

18-36 VDC

LASER

 

Wavelength

635-670 nm

Laser power

< 1 mW up to 20 mW

Laser class

2, 2M, 3R, 3B

Exposure time

3 – 2000 µs

Enclosure

 

Dimension

331x148x56 mm

13.03x5.83x2.2"

Weight

3.0 kg

6.6 lbs

Protections class

IP 65

Operating temperature

0 .. +40 °C

32 .. +104 °F

Storage temperature

-20 °C .. +70 °C

-4 °F .. +158 °F

Material

Lacquered aluminium

Interfaces

 

Service interface

RS232

HOST Interface

RS232

CAN-bus

up to 1Mbit/s

Analogue

0-20 mA, 4-20 mA

Synchronisation interface

Synchronizes the exposure time

Functions/Features

 

Measuring algorithm

Triangulation with modified "centre of gravity". Suppression of background light and second reflections.

Measurement functions

Distance

Distance+offset

Thickness

Filtering

Average 1..1000

Average selftrig

Average trig

Moving average

Average gate

Median 1..1000

Median trig

Median selftrig

Median gate

Adjustable median (0-100%)

* For a sensor with standoff=300 mm and measurement range=2000mm. Please, contact LIMAB for information about other sensor constellations.